Looking to replace the water heater in a room underneath the house with one of the heat pump water heaters.
Hybrid water heater condensate drain. Letting the hoses drain into a bucket eventually did cause a condensate alarm as well. It just takes more time 3 days to trip than if the hoses are connected to a drain 24h. Live outside the city limits so we re not bound by code. An optional ducting kit is now available to enable flexibility of installation in living areas and confined spaces for maximum comfort.
The recommendation is to get a condensate drain kit for convenient draining and metal drain pans to protect the room where the heater is installed. Measure the distance from the condensate drain pan cover to the condensate pump and cut two 18 awg or the system should be installed only with piping that is larger wires to correct length and strip the insulation at suitable for potable drinkable water such as copper both ends of each wire figure 7. Once power is off you ll need to drain the water from the old water heater. It s remotely possible that once in awhile the place where the drain pipe terminates is below the water level in the sump pit.
Hybrid electric water heaters we were proud to introduce the first hybrid electric heat pump water heater to the market in 2009 but we didn t stop there. The room has no drain the floors and walls are poured concrete. There are two drains one primary and one overflow located on the side of the water heater to manage removal of the condensate since the heater produces condensate a drain must be available in close proximity to the unit. The energy savings benefits of the heat pump hybrid water heater as compared to a standard 50 gallon electric tank water heater will still be significant.
These type heaters require a drain to carry off water from the heat pum. The drain must be no higher than 36 above the floor laundry drain is acceptable. Replaced all condensate lines still complains. Shut the power and water supply off to the old water heater and leave it off until the new water heater is installed.
This old house plumbing and heating contractor richard trethewey is in hot water again. Budgetslasher would you be willing to share a picture of your condensate line connection at the wh. Power vent and power direct vent heaters are equipped with the condensate drain so the water vapor from the exhaust gases will roll down the pvc vent pipe and through the drain port out. What are the local condensate drain codes for the.
Hybrid water heater complains condensate lines are blocked. See below for a shopping list and tools subscribe to this old hous.